| What it treats | Brain aneurysms, mainly large, wide-necked or fusiform ones that have not burst |
|---|---|
| Anaesthesia | General anaesthesia |
| Entry point | Needle puncture in the groin or wrist |
| Hospital stay | Usually a few days |
| Medicines | Two blood-thinning tablets before and for months after |
What is a flow diverter?
A flow diverter is a fine, tightly woven metal mesh tube placed inside the brain artery, across the opening (neck) of an aneurysm. Instead of filling the aneurysm, it rebuilds the artery wall. Blood is steered along the artery past the aneurysm, so blood inside the aneurysm slows, clots and seals off over time. The lining of the artery then grows over the mesh (UCLH).
Read about brain aneurysms for symptoms, warning signs and all the treatment options.
Who is it for?
Flow diverters are mainly used for aneurysms that have not burst and are hard to treat with coils alone (NICE MTG10), such as:
- large or giant aneurysms
- wide-necked aneurysms, where coils could slip out
- fusiform aneurysms, where a whole stretch of artery is widened rather than a single bulge
- aneurysms that have come back after earlier coiling
It may not suit people who cannot take blood-thinning tablets for several months, or some aneurysms that have just bled. Some aneurysms suit coiling, an intrasaccular device or open surgery (clipping) better.
How is it done?
- Medicines before. Two antiplatelet (blood-thinning) tablets are usually started some days before, and a blood test may check they are working.
- Anaesthesia. You are put to sleep with a general anaesthetic.
- Access. A thin tube (catheter) is passed into an artery through a needle puncture in the groin or wrist.
- Reaching the aneurysm. Under X-ray guidance, smaller tubes are guided up to the brain artery.
- Placing the flow diverter. The folded mesh tube is pushed out across the neck of the aneurysm, where it opens and presses against the artery wall. Sometimes coils are added inside the aneurysm too.
- Finishing. The tubes are removed and the puncture site is closed.
The procedure usually takes a few hours. Most people stay in hospital for a few days.
Recovery and follow-up
- Blood-thinning tablets are continued for months, usually two at first and then one long-term. Do not stop them on your own: stopping early can cause a clot on the mesh.
- Headache and tiredness for some days are common.
- Light activity within a week or two for most people; ask your team about work and driving.
- Follow-up scans (usually an angiogram or MR angiogram) check that the aneurysm has sealed. This often takes months.
What are the risks?
Possible risks include (UCLH):
- Stroke, from a clot blocking a small branch artery or, rarely, from bleeding
- Bleeding, including at the puncture site, more likely because of the blood-thinning tablets
- Narrowing inside the flow diverter over time
- The aneurysm not sealing fully, needing further treatment
- A reaction to the X-ray dye
The team will explain the risks that apply to your aneurysm before you decide.
Common questions about flow diverter
What is a flow diverter?
A soft, tightly woven metal mesh tube, similar to a stent, placed in the artery across the opening (neck) of the aneurysm. It redirects blood along the artery so the aneurysm slowly seals off.
How is a flow diverter different from coiling?
Coiling fills the aneurysm itself with coils. A flow diverter repairs the artery from the outside of the aneurysm, across its neck. Flow diverters are often used for large or wide-necked aneurysms that are hard to coil.
Why do I need blood-thinning tablets?
The mesh sits inside the artery, so two antiplatelet tablets are started before the procedure and continued for months afterwards to stop clots forming on it. Never stop them without your doctor's advice.
Does the aneurysm close straight away?
No. The aneurysm usually clots and shrinks gradually over weeks to months. Follow-up scans check that it has sealed.
Can a flow diverter be used for a burst aneurysm?
It is mainly used for aneurysms that have not burst, because of the need for strong blood-thinning medicines. For a burst aneurysm, coiling or clipping is usually preferred, though flow diverters are used in selected cases.
Sources
This page follows these patient resources and guidelines:
- Pipeline embolisation device for the treatment of complex intracranial aneurysms (MTG10) (NICE medical technologies guidance)
- Flow diverting stent treatment (patient information) (University College London Hospitals NHS Foundation Trust)
- Guidelines for the Management of Patients With Unruptured Intracranial Aneurysms (Thompson et al., 2015) (American Heart Association / American Stroke Association, Stroke)
Related
Brain Aneurysm
A bulge in a brain artery, often found by chance on a scan.
Learn more →Aneurysm Coiling
Seals a brain aneurysm from inside with tiny coils.
Learn more →Intrasaccular Device (WEB)
A small mesh basket placed inside a wide-necked aneurysm to seal it.
Learn more →
Who performs this procedure
Dr. Virender Sheorain, Director, Peripheral Vascular & Endovascular Sciences, Medanta – The Medicity, Gurugram. Trained at AIIMS New Delhi and in three fellowships in the USA.
Read Dr. Sheorain's profile →This is general information. Please consult the doctor for advice about your condition.